Variables
Description
What is this formula?
The interaction ratio is a simplified measure used to evaluate the combined effect of axial load and bending moment on a structural member. It compares the applied loads against the available design capacities.
When to use it
Use this formula as a preliminary check for columns, beam-columns, steel members, reinforced concrete members, and other structural elements subjected to combined axial force and bending.
Example
A steel column is subjected to:
P = 450 kN
Pn = 900 kN
M = 80 kN·m
Mn = 200 kN·m
Formula:
IR = P/Pn + M/Mn
Substitution:
IR = 450/900 + 80/200
IR = 0.50 + 0.40
Result:
IR = 0.90
Since IR < 1.0, the member satisfies this simplified interaction check.
Applications
Steel columns, beam-columns, reinforced concrete members, structural frames, bridge components, and preliminary structural design checks.
Note
This equation is a simplified interaction model commonly used for preliminary design and screening calculations. Actual design codes often employ more complex interaction equations that depend on slenderness, stability effects, material behavior, section type, and load combinations. The exact interaction expression may vary between design standards.