Formula library

Emission Rate from Stack Concentration

Emission Rate from Stack Concentration
\[Q = CAv\]

Variables

Qpollutant emission rate (mass/s)
Cpollutant concentration in stack gas (mass/volume)
Astack cross-sectional area (m²)
vstack gas velocity (m/s)

Description

What is this formula?

This formula calculates the pollutant emission rate from a stack using the measured pollutant concentration, gas velocity, and stack cross-sectional area.


When to use it

Use it when emissions monitoring data are available and a mass emission rate is required for environmental reporting, permitting, or dispersion modeling.


Example

Data:

C = 0.12 g/m³

A = 1.5 m²

v = 12 m/s


Formula:

Q = CAv


Substitution:

Q = 0.12 × 1.5 × 12


Result:

Q = 2.16 g/s


Applications

Stack testing, emissions inventories, regulatory reporting, air dispersion studies, and environmental compliance evaluations.


Note

This calculation assumes that the measured concentration and gas velocity are representative of the entire stack cross section. Accurate results require proper sampling procedures and representative flow measurements according to applicable standards.